Skip navigation

Electrical characteristics

Recommended operational characteristics:

parameter

min

max

unit

note

supply voltage

9

30

V

Voltage range at which the ASU module performs all the declared functions

current consumption

 

227

mA

It depends on the number of active channels, the total current of the loads, the supply voltage, the activity of the CAN bus. Typical value for the case of eight active channels and a voltage of 24 V is about 140 mA. If all channels are inactive, the current consumption does not exceed 10 mA.

Total output current

 

100

A

Depends on the ambient temperature.

current per output

 

20

A

Depends on the ambient temperature and total current

 

Critical operational characteristics:

parameter

max

unit

note

supply voltage

36

V

 

Reverse voltage

-32

V

 

total output current

150

A

Depends on the ambient temperature. For consultation, contact the NSE.

current per output

40

A

Depends on the ambient temperature. Short-term inrush currents can reach higher values. For consultation, contact the NSE.